At EDIBON, we are committed to strengthening skills as a strategic pillar for the competitiveness and social well-being of the European Union. Proper training not only boosts the economy but also enables individuals to fully participate in society and democracy.
BIETC Gerät für Elektrotherapie in der Biomedizin, Computergesteuert (PC)
INNOVATIVE SYSTEME
The Computer Controlled Biomedical Electrotherapy Teaching Unit, "BIETC", has been designed by EDIBON to study, in an experimental way, the low, medium and high frequency waves effects in human tissues and acquire the necessary knowledge to work with electrotherapy unit.
ÄHNLICHE NEUIGKEITEN
ALLGEMEINE BESCHREIBUNG
The Computer Controlled Biomedical Electrotherapy Teaching Unit, "BIETC", consists of an electrotherapy machine used in a professional field , and a control interface box.
The control interface box has the connection to the PC to acquire the signals from the electrotherapy unit. Inside the control box are located:
The signal analyser for the two channels of the electrotherapy unit.
The skin emulator: containing the simulation of three different types of skins, each one with different electrical impedance.
The electrotherapy unit allows the user to set the desired electrotherapy programme and configuration, to perform the test on the skin emulator.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a Control Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and Data Management Software Packages, for controlling the process and all parameters involved in the process.
ÜBUNGEN UND GEFÜHRTE PRAKTIKEN
GEFÜHRTE PRAKTISCHE ÜBUNGEN IM HANDBUCH ENTHALTEN
- Understanding the different effects of the low and medium frequency currents in the human tissues.
- Testing the effects of the electrotherapy waves according to the different factors involved in this type of therapy (frequency, tissues resistance, waveform, etc.).
- Understanding different application examples: iontophoresis, ease pain, etc.
MEHR PRAKTISCHE ÜBUNGEN FÜR DAS GERÄT
- Study of the therapeutic applications of electricity. Other possibilities to be done with this unit:
- Many students view results simultaneously. To view all results in real time in the classroom by means of a projector or an electronic whiteboard.
- Open Control, Multicontrol and Real Time Control. This unit allows intrinsically and/or extrinsically to change the span, gains, proportional, integral, derivative parameters, etc, in real time.
- The Computer Control System with SCADA allows a real industrial simulation.
- This unit is totally safe as uses mechanical, electrical/electronic and software safety devices.
- This unit can be used for doing applied research.
- This unit can be used for giving training courses to Industries even to other Technical Education Institutions.
- Control of the BIETC unit process through the control interface box without the computer.
- Visualization of all the sensors values used in the BIETC unit process.
- Several other exercises can be done and designed by the user.
ERGÄNZENDE AUSRÜSTUNG
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIHBPC
The Computer Controlled Biomedical Human Biosignals and Parameters Teaching Unit, "BIHBPC", allows the students to learn how to interpret and perform the most important biosignal measurements: Electrocardiography (ECG), Pulse oximetry (SpO₂),...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIPBSC
Gerät zur Simulation von Bio-Signalen von Patienten in der Biomedizin, computergesteuert (PC)
The monitoring of a patient carries the most relevant information for a doctor to know how this patient is reacting to a certain treatment.This monitoring consists on the measurement of different biosignals to understand the physicochemical and...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BISBC
Gerät für Spirometrie in der Biomedizin, computergesteuert (PC)
The Computer Controlled Spirometry Teaching Unit, "BISBC", consists of a professional spirometer and a breath simulator composed by an electrical linear actuator and two lung simulators. The lung simulators have similar volumes to the human lungs...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BICIR
Gerät für Elektrochirurgie in der Biomedizin
The Unit for Study of Electrosurgery in Biomedicine, "BICIR", consists of an electrosurgical unit used in modern medicine to cut tissues, restrict blood flow and improve the surgeon’s visibility during interventions. The unit includes a protective...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BICSC
Gerät für Kreislaufsystem in der Biomedizin, Computergesteuert (PC)
The Computer Controlled Biomedical Circulatory System Teaching Unit, "BICSC", allows the students to learn how to interpret the results obtained by the viscometer and pressure sensors, and apply them for the diagnosis of circulatory problems.The...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIUTEC
Gerät für Ultraschall in der Biomedizin, computergesteuert (PC)
The Computer Controlled Biomedical Ultrasound Thermal Effects Teaching Unit, "BIUTEC", has been designed by EDIBON to study, in an experimental way, the ultrasound effects in biological tissues and acquire the necessary knowledge to design and...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIADC
Gerät für Diagnose und Audiometrie in der Biomedizin, Computergesteuert (PC)
The Computer Controlled Biomedical Auditory Diagnostic Teaching Unit, "BIADC", allows the students to analyse the audiograms corresponding to individuals with different audition levels, in order to diagnose possible hearing impairments.The...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIMAG
Gerät für Magnettherapie in der Biomedizin
The Biomedical Magnetotherapy Teaching Unit, "BIMAG" allows the students to test magnetotherapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Magnetotherapy Teaching Unit, "BIMAG" includes:Real model...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIMTE
Gerät für Thermische Effekte von Mikrowellen in der Biomedizin
The Biomedical Microwave Thermal Effects Teaching Unit, "BIMTE", allows the students to test microwave therapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Microwave Thermal Effects Teaching Unit,...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIEV
Dampfsterilisator, computergesteuert (PC)
The Computer Controlled Steam Sterilization, "BIEV", is a real unit used in many medical and research centers for the correct sterilization of the typical instruments used, avoiding possible contaminating effects produced by infectious...