At EDIBON, we are committed to strengthening skills as a strategic pillar for the competitiveness and social well-being of the European Union. Proper training not only boosts the economy but also enables individuals to fully participate in society and democracy.
BIUTEC Ultraschall-Ausstattung in der Biomedizin, Computergesteuert (PC)
INNOVATIVE SYSTEME
The Computer Controlled Biomedical Ultrasound Thermal Effects Teaching Unit, "BIUTEC", has been designed by EDIBON to study, in an experimental way, the ultrasound effects in biological tissues and acquire the necessary knowledge to design and validate therapeutic ultrasound units.
ÄHNLICHE NEUIGKEITEN
ALLGEMEINE BESCHREIBUNG
The Computer Controlled Biomedical Ultrasound Thermal Effects Teaching Unit, "BIUTEC", has been designed by EDIBON to study, in an experimental way, the ultrasound effects in biological tissues and acquire the necessary knowledge to design and validate therapeutic ultrasound units.
The unit is supplied with a set of practical exercises that will help the student to understand how to configure a therapeutic ultrasound device.
The Computer Controlled Biomedical Ultrasound Thermal Effects Teaching Unit,"BIUTEC", consists of a professional therapeutic ultrasound machine and a biologicaltissue simulator, composed of three different material layers with a thermocouple ineach one.
The simulator’s materials have similar acoustic properties to the human skin,soft tissue and bone with the aim of study the thermal effect produced by ultrasoundtherapy.
Besides, the unit is supplied with different applicators to study the effect of theemitting area.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a ControlInterface Box + a Data Acquisition Board + Data Acquisition and Data Management Software Packages, for controlling the process andall parameters involved in the process.
ÜBUNGEN UND GEFÜHRTE PRAKTIKEN
GEFÜHRTE PRAKTISCHE ÜBUNGEN IM HANDBUCH ENTHALTEN
- Study of the thermal effect according to the duty cycle.
- Study of the thermal effect according to the frequency.
- Study of the thermal effect according to the effective emission area (ERA).
- Study of the nonthermal effect according to the duty cycle.
- Study of the nonthermal effect according to the frequency.
- Study of the power dissipation according to the frequency.
- Sensor calibration.
MEHR PRAKTISCHE ÜBUNGEN FÜR DAS GERÄT
- Many students view results simultaneously. To view all results in real time in the classroom by means of a projector or an electronic whiteboard.
- The Computer Control System with SCADA allows a real industrial simulation.
- This unit is totally safe as uses mechanical, electrical and electronic, and software safety devices.
- This unit can be used for doing applied research.
- This unit can be used for giving training courses to Industries even to other Technical Education Institutions.
- Control of the BIUTEC unit process through the control interface box without the computer.
- Visualization of all the sensors values used in the BIUTEC unit process.
- Several other exercises can be done and designed by the user.
ERGÄNZENDE AUSRÜSTUNG
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIHBPC
The Computer Controlled Biomedical Human Biosignals and Parameters Teaching Unit, "BIHBPC", allows the students to learn how to interpret and perform the most important biosignal measurements: Electrocardiography (ECG), Pulse oximetry (SpO₂),...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIPBSC
Patienten-Biosignal-Simulationseinrichtung in der Biomedizin, Computergesteuert (PC)
The monitoring of a patient carries the most relevant information for a doctor to know how this patient is reacting to a certain treatment.This monitoring consists on the measurement of different biosignals to understand the physicochemical and...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BISBC
Spirometrie-Ausstattung in der Biomedizin, Computergesteuert (PC)
The Computer Controlled Spirometry Teaching Unit, "BISBC", consists of a professional spirometer and a breath simulator composed by an electrical linear actuator and two lung simulators. The lung simulators have similar volumes to the human lungs...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BICIR
Elektrochirurgie-Ausstattung in der Biomedizin
The Unit for Study of Electrosurgery in Biomedicine, "BICIR", consists of an electrosurgical unit used in modern medicine to cut tissues, restrict blood flow and improve the surgeon’s visibility during interventions. The unit includes a protective...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BICSC
Kreislaufsystem-Ausstattung in der Biomedizin, Computergesteuert (PC)
The Computer Controlled Biomedical Circulatory System Teaching Unit, "BICSC", allows the students to learn how to interpret the results obtained by the viscometer and pressure sensors, and apply them for the diagnosis of circulatory problems.The...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIETC
Elektrotherapie-Ausstattung in der Biomedizin, Computergesteuert (PC)
The Computer Controlled Biomedical Electrotherapy Teaching Unit, "BIETC", consists of an electrotherapy machine used in a professional field , and a control interface box.The control interface box has the connection to the PC to acquire the...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIADC
Diagnose- und Hörgeräteausstattung in der Biomedizin, Computergesteuert (PC)
The Computer Controlled Biomedical Auditory Diagnostic Teaching Unit, "BIADC", allows the students to analyse the audiograms corresponding to individuals with different audition levels, in order to diagnose possible hearing impairments.The...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIMAG
Magnetotherapie-Ausstattung in der Biomedizin
The Biomedical Magnetotherapy Teaching Unit, "BIMAG" allows the students to test magnetotherapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Magnetotherapy Teaching Unit, "BIMAG" includes:Real model...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIMTE
Gerät für Diagnose und Audition in der Biomedizin, Computergesteuert (PC)
The Biomedical Microwave Thermal Effects Teaching Unit, "BIMTE", allows the students to test microwave therapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Microwave Thermal Effects Teaching Unit,...
14.3.- BIOMEDIZINISCHE AUSRÜSTUNG
BIEV
Dampfsterilisator, Computergesteuert (PC)
The Computer Controlled Steam Sterilization, "BIEV", is a real unit used in many medical and research centers for the correct sterilization of the typical instruments used, avoiding possible contaminating effects produced by infectious...