Biomedical engineering is an interdisciplinary field that synergizes principles from both engineering and biology to design, develop, and sustain technological solutions tailored for medical and healthcare applications.
BIPBSC Unit Simulasi Biosinyal Pasien Biomedis, Dikendalikan dari Komputer (PC)
SISTEM INOVATIF
The Computer Controlled Biomedical Patient Biosignals Simulator, "BIPBSC", is a complete unit which allows the user to simulate the main Biosignals of a patient and to monitor them in a real in a real patient monitor. It includes a patient simulator, which imitates the Biosignals that can be studied by the unit.
BERITA TERKAIT
GAMBARAN UMUM
The monitoring of a patient carries the most relevant information for a doctor to know how this patient is reacting to a certain treatment.
This monitoring consists on the measurement of different biosignals to understand the physicochemical and physiological processes in the patient.
The Computer Controlled Biomedical Patient Biosignals Simulator, "BIPBSC", is a complete unit which allows the user to simulate the main Biosignals of a patient and to monitor them in a real in a real patient monitor. It includes a patient simulator, which imitates the Biosignals that can be studied by the unit.
The Computer Controlled Biomedical Patient Biosignals Simulator, "BIPBSC", unit is provided with a set of practical exercises, through which the user will understand the basic principles about the monitoring of a patient in a realistic clinical environment, as well as interpret the most important Biosignals patterns.
The Computer Controlled Biomedical Patient Biosignals Simulator, "BIPBSC", unit allows the students to learn how to interpret and perform the most important biosignal measurements: Electrocardiography (ECG), Pulse oximetry (SpO2), Blood Pressure (BP) and Capnography (etCO2).
A Patient simulator mimics the above-mentioned biological signals (among others) by means of a software with different programmable scenarios of healthy and ill patients. Also, a real vital signs patient monitor can be connected to the mannequin for the real measurement of the simulated signals.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a Control Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and Data Management Software Packages, for controlling the process and all parameters involved in the process.
LATIHAN DAN PRAKTEK PEDOMAN
LATIHAN PRAKTIS YANG DIANDAL TERMASUK DALAM PANDUAN
- Basic principles of biosignals acquisition.
- Understanding of biosignal measuring devices.
- Interpretation of the ECG normal pattern.
- Analysis of ECG pattern changes.
- Interpretation of the SpO2 normal pattern.
- Analysis of SpO2 pattern changes.
- Interpretation of the etCO2 normal pattern.
- Analysis of etCO2 pattern changes.
- Interpretation of the non-invasive blood pressure normal pattern.
- Analysis of non-invasive blood pressure pattern changes.
- Interpretation of the invasive blood pressure normal pattern (ABP,PAP and CVP).
- Analysis of invasive blood pressure (ABP, PAP and CVP) pattern changes.
- Understanding the reaction that certain drugs have onbiopotentials.
- Cardiopulmonary resuscitation (CPR).
- Basic principles of pacemakers.
- Analysis of the patient ECG stimulated by a transcutaneous pacemaker.
LEBIH BANYAK LATIHAN PRAKTIS YANG AKAN DILAKUKAN DENGAN UNIT
- Many students view results simultaneously.To view all results in real time in the classroom by means of aprojector or an electronic whiteboard.
- Open Control, Multicontrol and Real Time Control.This unit allows intrinsically and/or extrinsically to change thespan, gains, proportional, integral, derivative parameters, etc,in real time.
- The Computer Control System with SCADA allows a realindustrial simulation.
- This unit is totally safe as uses mechanical, electrical/electronic,and software safety devices.
- This unit can be used for doing applied research.
- This unit can be used for giving training courses to Industrieseven to other Technical Education Institutions.
- Control of the BIPBSC unit process through the control interfacebox without the computer.
- Several other exercises can be done and designed by the user.
PERALATAN SIMILAR TERSEDIA
14.3.- PERALATAN BIOMEDIS
BIHBPC
The Computer Controlled Biomedical Human Biosignals and Parameters Teaching Unit, "BIHBPC", allows the students to learn how to interpret and perform the most important biosignal measurements: Electrocardiography (ECG), Pulse oximetry (SpO₂),...
PERALATAN KOMPLEMENTER
14.3.- PERALATAN BIOMEDIS
BIHBPC
Unit Parameter dan Biosinyal Biomedis, Dikendalikan dari Komputer (PC)
The Computer Controlled Biomedical Human Biosignals and Parameters Teaching Unit, "BIHBPC", allows the students to learn how to interpret and perform the most important biosignal measurements: Electrocardiography (ECG), Pulse oximetry (SpO₂),...
14.3.- PERALATAN BIOMEDIS
BISBC
Unit Spirometri Biomedis, Dikendalikan dari Komputer (PC)
The Computer Controlled Spirometry Teaching Unit, "BISBC", consists of a professional spirometer and a breath simulator composed by an electrical linear actuator and two lung simulators. The lung simulators have similar volumes to the human lungs...
14.3.- PERALATAN BIOMEDIS
BICIR
Unit Elektrokirurgi Biomedis
The Unit for Study of Electrosurgery in Biomedicine, "BICIR", consists of an electrosurgical unit used in modern medicine to cut tissues, restrict blood flow and improve the surgeon’s visibility during interventions. The unit includes a protective...
14.3.- PERALATAN BIOMEDIS
BICSC
Unit Sistem Peredaran Darah Biomedis, Dikendalikan dari Komputer (PC)
The Computer Controlled Biomedical Circulatory System Teaching Unit, "BICSC", allows the students to learn how to interpret the results obtained by the viscometer and pressure sensors, and apply them for the diagnosis of circulatory problems.The...
14.3.- PERALATAN BIOMEDIS
BIETC
Unit Elektroterapi Biomedis, Dikendalikan dari Komputer (PC)
The Computer Controlled Biomedical Electrotherapy Teaching Unit, "BIETC", consists of an electrotherapy machine used in a professional field , and a control interface box.The control interface box has the connection to the PC to acquire the...
14.3.- PERALATAN BIOMEDIS
BIUTEC
Unit Ultrasonografi Biomedis, Dikendalikan dari Komputer (PC)
The Computer Controlled Biomedical Ultrasound Thermal Effects Teaching Unit, "BIUTEC", has been designed by EDIBON to study, in an experimental way, the ultrasound effects in biological tissues and acquire the necessary knowledge to design and...
14.3.- PERALATAN BIOMEDIS
BIADC
Unit Diagnosa dan Pendengaran Biomedis, Dikendalikan dari Komputer (PC)
The Computer Controlled Biomedical Auditory Diagnostic Teaching Unit, "BIADC", allows the students to analyse the audiograms corresponding to individuals with different audition levels, in order to diagnose possible hearing impairments.The...
14.3.- PERALATAN BIOMEDIS
BIMAG
Unit Magnetoterapi Biomedis
The Biomedical Magnetotherapy Teaching Unit, "BIMAG" allows the students to test magnetotherapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Magnetotherapy Teaching Unit, "BIMAG" includes:Real model...
14.3.- PERALATAN BIOMEDIS
BIMTE
Unit Efek Termal Gelombang Mikro dalam Biomedis
The Biomedical Microwave Thermal Effects Teaching Unit, "BIMTE", allows the students to test microwave therapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Microwave Thermal Effects Teaching Unit,...
14.3.- PERALATAN BIOMEDIS
BIEV
Sterilisasi Uap, Dikendalikan dari Komputer (PC)
The Computer Controlled Steam Sterilization, "BIEV", is a real unit used in many medical and research centers for the correct sterilization of the typical instruments used, avoiding possible contaminating effects produced by infectious...