At EDIBON, we are committed to strengthening skills as a strategic pillar for the competitiveness and social well-being of the European Union. Proper training not only boosts the economy but also enables individuals to fully participate in society and democracy.
BIADC コンピュータ制御の生体医学診断および聴覚ユニット
革新的なシステム
The Computer Controlled Biomedical Auditory Diagnostic Teaching Unit, "BIADC", performs an audiometry test and displays its results with a diagnostic aim. It also allows the simulation of different hearing loss profiles via software.
関連ニュース
概要
The Computer Controlled Biomedical Auditory Diagnostic Teaching Unit, "BIADC", allows the students to analyse the audiograms corresponding to individuals with different audition levels, in order to diagnose possible hearing impairments.
The Computer Controlled Biomedical Auditory Diagnostic Teaching Unit, "BIADC", includes:
- Audiometer: Real device used to perform the audiometry test and analyse its results.
- Ear simulator: Imitates the auditory function.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a Control Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and Data Management Software Packages, for controlling the process and all parameters involved in the process.
演習と指導の慣行
マニュアルに含まれるガイド付き実習
- Interpretation of a normal audiogram.
- Interpretation of an audiogram with sensorineural hearing loss.
- Interpretation of an audiogram with conductive hearing loss.
- Interpretation of an audiogram with mixed hearing loss.
- Interpretation of an audiogram with lateralization.
- Creation of an audiogram manually.
より実用的な練習をして、ユニットを完成させる
- Many students view results simultaneously. To view all results in real time in the classroom by means of a projector or an electronic whiteboard.
- Open Control, Multicontrol and Real Time Control. This unit allows intrinsically and/or extrinsically to change the span, gains, proportional, integral, derivative parameters, etc, in real time.
- The Computer Control System with SCADA allows a real industrial simulation.
- This unit is totally safe as uses mechanical, electrical/electronic, and software safety devices.
- This unit can be used for doing applied research.
- This unit can be used for giving training courses to Industries even to other Technical Education Institutions.
- Control of the BIADC unit process through the control interface box without the computer.
- Visualization of all the sensors values used in the BIADC unit process.
- Several other exercises can be done and designed by the user.
補完的な機器
14.3.- 生物医学機器
BIHBPC
The Computer Controlled Biomedical Human Biosignals and Parameters Teaching Unit, "BIHBPC", allows the students to learn how to interpret and perform the most important biosignal measurements: Electrocardiography (ECG), Pulse oximetry (SpO₂),...
14.3.- 生物医学機器
BIPBSC
コンピュータ制御の生体医学患者バイオシグナルシミュレーションユニット
The monitoring of a patient carries the most relevant information for a doctor to know how this patient is reacting to a certain treatment.This monitoring consists on the measurement of different biosignals to understand the physicochemical and...
14.3.- 生物医学機器
BISBC
コンピュータ制御の生体医学肺機能ユニット
The Computer Controlled Spirometry Teaching Unit, "BISBC", consists of a professional spirometer and a breath simulator composed by an electrical linear actuator and two lung simulators. The lung simulators have similar volumes to the human lungs...
14.3.- 生物医学機器
BICIR
生体医学電気外科ユニット
The Unit for Study of Electrosurgery in Biomedicine, "BICIR", consists of an electrosurgical unit used in modern medicine to cut tissues, restrict blood flow and improve the surgeon’s visibility during interventions. The unit includes a protective...
14.3.- 生物医学機器
BICSC
コンピュータ制御の生体医学循環器ユニット
The Computer Controlled Biomedical Circulatory System Teaching Unit, "BICSC", allows the students to learn how to interpret the results obtained by the viscometer and pressure sensors, and apply them for the diagnosis of circulatory problems.The...
14.3.- 生物医学機器
BIETC
コンピュータ制御の生体医学電気療法ユニット
The Computer Controlled Biomedical Electrotherapy Teaching Unit, "BIETC", consists of an electrotherapy machine used in a professional field , and a control interface box.The control interface box has the connection to the PC to acquire the...
14.3.- 生物医学機器
BIUTEC
コンピュータ制御の生体医学超音波ユニット
The Computer Controlled Biomedical Ultrasound Thermal Effects Teaching Unit, "BIUTEC", has been designed by EDIBON to study, in an experimental way, the ultrasound effects in biological tissues and acquire the necessary knowledge to design and...
14.3.- 生物医学機器
BIMAG
生体医学磁気療法ユニット
The Biomedical Magnetotherapy Teaching Unit, "BIMAG" allows the students to test magnetotherapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Magnetotherapy Teaching Unit, "BIMAG" includes:Real model...
14.3.- 生物医学機器
BIMTE
バイオメディカルマイクロ波熱効果ユニット
The Biomedical Microwave Thermal Effects Teaching Unit, "BIMTE", allows the students to test microwave therapy, so as to achieve a better knowledge on its functioning and internal mechanism.The Biomedical Microwave Thermal Effects Teaching Unit,...
14.3.- 生物医学機器
BIEV
チーム滅菌器、コンピュータ制御(PC)
The Computer Controlled Steam Sterilization, "BIEV", is a real unit used in many medical and research centers for the correct sterilization of the typical instruments used, avoiding possible contaminating effects produced by infectious...