AEL-AE4 差動自動遮断器の応用
革新的なシステム
The Differential Automatic Switches Application, "AEL-AE4", has been designed by EDIBON to demonstrate how a differential protection switch works when an earth leakage occurs.
研究室
関連ニュース
概要
The Differential Automatic Switches Application, "AEL-AE4", has been designed by EDIBON to demonstrate how a differential protection switch works when an earth leakage occurs.
This application includes all necessary elements to understand the behavior of a differential protection switch. In order to test the differential protection this application includes a series of modules that allow to trigger an earth leakage with aid of a variable resistor load. Thus, it will be possible to measure the trip current threshold of the differential switch.
This application includes modules such us analog voltmeter and ammeter to measure fault currents and voltages, tester protection module, fault injection module, etc.
演習と指導の慣行
マニュアルに含まれるガイド付き実習
- Verification of the operation of the main power supply.
- Verification of the operation of the single-phase transformer with galvanic isolation.
- Study of basic differential protection.
- Study of differential protection sensitivity.
- Study of earth leakage faults with variable earth impedance.
- Measurement of contact voltage with different contact impedance.
- Measurement of earth leakage currents with different contact impedance.
より実用的な練習をして、ユニットを完成させる
- Several other exercises can be done and designed by the user.
利用可能な類似の機器
補完的な機器
インターコムの適用
インターコムの適用(音声とビデオ)
明るさ制御応用
基本的な明るさ制御応用
位置スイッチの応用
タイマー照明応用
電気工学の応用(照明)
暖房制御の応用
基本的な暖房制御の応用
品質

アフターサービス