Transformes are electrical machines whose purpose is to modify the voltage values at certain points of the electrical networks. Nowadays, it would be unfeasible to transport and distribute energy along the transmission and distribuction lines wothout these machines.

查看一般說明

一般說明

The Auxiliary Transformer and Protection Units, "AUTP", are a range of auxiliary single phase and three phase transformers used to adapt the voltage level of any country in the appropriate voltage for EDIBON units. They have an input voltage range and an output range of voltage to suit the electrical grid of every country. The versions available are:

  • EMPTA-1PH/4K. Single-Phase Auxiliary Transformer and Protection Unit. This unit is an auxiliary single phase transformer used to adapt the voltage level of any country in the appropriate voltage for EDIBON units for a single phase grid. It has a variable input voltage range of 110 VAC – 127 VAC and an output range of 200 VAC – 240 VAC.

Its 4000 VA of nominal power gives it the possibility to be connected to any single phase EDIBON unit.

The 4 kVA 3PH Auxiliary and Protection Transformer, "EMPTA-1PH/4K ", includes all necessary protections for a maximum safety. It includes a magnetothermal differential protection, fuses and input and output safety plugs in the transformer.

  • EMPTA-UL/CSA. Single-Phase Auxiliary Transformer and Protection Unit. This unit is an auxiliary single phase transformer used to adapt the voltage level of any country in the appropriate voltage for EDIBON units for a single phase grid. It has a variable input voltage range of 110 VAC – 127 VAC and an output range of 200 VAC – 240 VAC.

Its 4000 VA of nominal power gives it the possibility to be connected to any single phase EDIBON unit.

The EMPTA for getting UL or CSA Certification in the USA or Canada, "EMPTA-UL/CSA", includes all necessary protections for a maximum safety. It includes a magnetothermal differential protection, fuses and input and output safety plugs in the transformer.

  • EMPTA-3PH/7K. Three-Phase Auxiliary Transformer and Protection Unit. This unit is an auxiliary three phase transformer used to adapt the voltage level of any country in the appropriate voltage for EDIBON units for a three phase grid. It has a variable input voltage range of 190 VAC – 240 VAC and an output range of 380 VAC – 400 VAC.

Its 7000 VA of nominal power gives it the possibility to be connected to any three phase EDIBON unit up to 7000 VA.

The 7 kVA 3PH Auxiliary and Protection Transformer, "EMPTA-3PH/7K ", includes all necessary protections for a maximum safety. It includes a magnetothermal differential protection, fuses and input and output safety plugs in the transformer.

  • EMPTA-3PH/12K. 12 KVA Three-Phase Auxiliary Transformer and Protection Unit. This unit is an auxiliary three phase transformer used to adapt the voltage level of any country in the appropriate voltage for EDIBON units for a three phase grid. It has a variable input voltage range of 190 VAC – 240 VAC and an output range of 380 VAC – 400 VAC.

Its 12000 VA of nominal power gives it the possibility to be connected to any three phase EDIBON unit up to 12000 VA.

The 12 kVA 3PH Auxiliary and Protection Transformer, "EMPTA-3PH/12K ", includes all necessary protections for a maximum safety. It includes a magnetothermal differential protection, fuses and input and output safety plugs in the transformer.