WIT-IEP Wiring Installation Training for Industrial Electrical Protections

WIRING INSTALLATION TRAINING FOR INDUSTRIAL ELECTRICAL PROTECTIONS - WIT-IEP

INNOVATIVE SYSTEMS

The Wiring Installation Training, Industrial Electrical Protections application, "WIT-IEP", has been designed by EDIBON for the formation at professional-practical level in the field of the installations, wiring and testing of electrical protections present in industry.

See general description

RELATED NEWS

General Description

The Wiring Installation Training, Industrial Electrical Protections application, "WIT-IEP", has been designed by EDIBON for the formation at professional-practical level in the field of the installations, wiring and testing of electrical protections present in industry.

This application provides the future professionals with knowledge and essential skills on the assembly, installation, wiring and testing of industrial electrical protection. This application also offers different kits to provide experience in the installation of numerous protection elements that combining them can implement different protection systems.

To acquire a complete knowledge, the application includes a specific manual in which is explained, at theoretical-practical level, the aspects concerning to the installation procedures and wiring of these installations.

Exercises and guided practices

GUIDED PRACTICAL EXERCISES INCLUDED IN THE MANUAL

  1. Identification of connections and wiring of two-pole differential circuit breaker of type AC.
  2. Identification of connections and wiring of two-pole differential circuit breaker of type A.
  3. Identification of connections and wiring of four-pole differential circuit breaker of type A.
  4. Identification of connections and wiring of two-pole magnetothermal circuit breaker.
  5. Identification of connections and wiring of two-pole magnetothermal circuit breaker.
  6. Identification of connections and wiring of magnetothermal circuit breaker for installations with neutral.
  7. Identification of connections and wiring of magnetothermal circuit breaker for installations without neutral.
  8. Identification of connections and wiring of thermal relay.
  9. Identification of connections and wiring of electronic relay for overloads.
  10. Identification of connections and wiring of transient voltage suppressor.
  11. Installation of the isolation transformer.
  12. Installation of protection fuses.
  13. Checking the selective degree of the electrical protections.
  14. Checking the trip current/time of magnetothermal circuit breaker according to tripping curve C.
  15. Checking the trip current/time of magnetothermal circuit breaker according to tripping curve B.
  16. Setting the tripping current of the thermal relay.
  17. Setting the tripping current of the electronic relay for overloads.
  18. Wiring of the single-phase transformer.
  19. Wiring of the three-phase transformer (optional).
  20. Simulation of earth fault and protection selectivity (optional).
  21. Injection of differential current for the differential circuit breakers operation (optional).
  22. Injection of current for the magnetothermal circuit breakers operation (optional).
  23. Earth fault simulation with multifunction unit.

MORE PRACTICAL EXERCISES TO BE DONE WITH THE UNIT

  1. Several other exercises can be done and designed by the user.

Quality

AFTER-SALES SERVICE

Ask for information